It’s no secret that smoke alarms save lives. Between the mid-1970’s and today the percentage of homes with at least one smoke alarm has gone from about 10% to around 96%, according to a recent survey. Having a working smoke alarm cuts the chances of dying in a reported fire in half, according to the National Fire Protection Association.
But there does seem to be a secret – a very well-kept secret – about the two types of smoke alarms that are available.
About 94% of the smoke alarms in U.S. homes are ionization type smoke alarms, while only about 6% are photoelectric. These different types of alarms react very differently to different types of fires, and this difference can add up to precious minutes that you may need to escape from a fire.
In general, ionization alarms respond slightly faster to flaming fires – about 10 to 15 seconds faster than photoelectric alarms. But when dealing with smoldering fires, ionization alarms respond as much as 30 to 60 minutes slower than photoelectric. That’s right, 30 to 60 minutes – not seconds. This drastic lag in responding to smoldering fires makes ionization alarms unacceptable to a growing chorus of fire protection specialists.
Smoldering fires are not only more deadly, they are very common and becoming more so as synthetic materials continue to be used more and more in our homes. And yet the type of smoke alarm present in 94% of U.S. homes may be an hour late in responding to these types of fires. It’s clear that photoelectric smoke alarms are the safer type.
A study at Texas A&M University from 1995 concluded that for a smoldering fire the probability of a fatality due to the failure of a photoelectric alarm was 4%, while the probability of a fatality due to the failure of an ionization alarm was 56%. For flaming fires the probability of a fatality due to the failure of a photoelectric alarm was again 4%, while the probability of a fatality due to the failure of an ionization alarm was 20%.
Underwriters Laboratory, which sets standards for smoke alarm performance, published the Smoke Characterization Study in 2007. They tested both ionization and photoelectric smoke alarms using the two existing test standards and with traditional test materials. They also tested the alarms using a variety of synthetic materials, and toast. Ionization alarms failed the UL tests 20% of the time using the traditional test materials. And remember, this is the same test that these alarms are supposed to pass just to be offered for sale in the U.S. When tested using newer synthetic materials, ionization alarms had a failure rate of 100%. On the other hand, photoelectric alarms has a pass rate of 100%. There was only one material for which ionization alarms outperformed photoelectric – burnt toast. Let me summarize: for the most common type of fire, ionization alarms had a 100% failure rate, while photoelectric alarms had a 100% pass rate.
This leads to the other problem with ionization alarms. They are notoriously susceptible to nuisance tripping, from cooking, showering, and other common activities. So they are commonly disabled. In fact, ionization alarms are up to 8 times more likely to be intentionally disabled. A disabled alarm of any type is of no value at all. Combination smoke alarms with both photoelectric and ionization detectors are available. But there are no industry standards for these dual detector alarms, and the manufacturers can adjust the alarm points of the two detectors so that the unit behaves no better than a photoelectric-only alarm. The International Association of Fire Fighters recommends against installing combination smoke alarms.
Finally, if you want to know what type you have, here are some guidelines. If the label mentions radioactive material, Americium-241, or if the model number has an “i” in it, then it is almost certainly an ionization alarm. If you’re not sure, then you should assume it’s ionization and replace it with a photoelectric type. The life you may save is precious.
More Posts You May Find Interesting
Radiator Bleeding
There are two basic types of boiler/radiator systems. One type is the steam boiler, where the boiler actually boils the water in the system and that steam then flies through the pipes to the radiators,
fan coil units
Fan coil units are a very common way to heat and cool the individual apartments in high rise and other multi-unit buildings. Here’s some information on fan coil units. In some buildings heat and cooling
GeneralAire Model 800 Humidifier
The GeneralAire Model 800 humidifier is a notoriously terrible, old fashioned, and obsolete humidifier. But even terrible devices deserve their moment in the sun, so here’s a little bit of information about it. All you’ll
Stair dimensions
Here are some of the rules that govern stairs, including the riser heights and the tread depths. As usual though, there are plenty of disclaimers and things to keep in mind. These rules come from
Filter slot
In many cases you should take some care to seal up the slot where your furnace filter slides into. Sometimes there will be a cover that screws on or clips on, and sometimes there will
Dates for GFCI requirements
Electrical codes have changed substantially over the last couple of decades. New products and new technologies have come onto the market, sometimes on their own and sometimes at the insistence of the code-making authorities. But